Infrared Optics: Materials, Filters and Windows for IR Systems

Infrared Optics: Materials, Filters and Windows for IR Systems

Infrared optics covers a broad range, from the near-infrared just beyond the visible (roughly 700 nm to 2.5 µm) through the short-, mid- and long-wave bands used in thermal imaging. Each band has its own materials and design rules, and choosing the wrong substrate is the fastest way to build an IR system that does not work.

Near-IR systems, such as night-vision cameras and fiber communications, can often use conventional optical materials. Fused silica and borosilicate glass transmit into the near-IR, and standard coatings work well. Our LP890 infrared longpass filter is designed to pass near-IR while blocking visible light — a typical night-vision requirement.

For IR-cut applications in colour cameras, the opposite is needed: transmit visible light and block near-IR so that the sensor records natural colours. An IR-cut 650 shortpass filter removes wavelengths above about 650 nm and is one of the most widely used filters in imaging.

Beyond about 2 µm, ordinary glasses become opaque and you must switch to infrared-transmitting materials. Infrared glass HWB-760 and related grades serve parts of the near- and mid-IR, while crystalline materials such as germanium, silicon, zinc selenide and chalcogenide glasses cover the thermal bands.

Sapphire is a versatile bridge material, transmitting from the UV through the visible and well into the infrared while being extremely hard and chemically durable. It is used for protective windows in harsh environments; see our sapphire window range.

Coatings in the IR need to be designed for the band. A visible AR coating does nothing at 10 µm, and many common coating materials absorb in the mid- and far-IR. IR coatings use materials such as germanium, zinc sulfide and chalcogenide films, and they are usually specified for a particular atmospheric window such as 3–5 µm or 8–12 µm.

Detector choice drives the optical design. InGaAs sensors cover roughly 0.9–1.7 µm, while microbolometers used in thermal cameras work in the 8–14 µm range. The optics, filter and window must all be matched to the detector's spectral response; there is no value in transmitting wavelengths the sensor cannot see.

Environmental durability varies widely across IR materials. Germanium is hard but brittle and has a high refractive index requiring AR coatings; some chalcogenide glasses are soft; zinc selenide is robust but toxic to machine. Consider the operating environment carefully, especially for outdoor or industrial thermal systems.

Thermal effects are more pronounced in the IR. Temperature changes can shift filter cut-offs and coating performance, and thermal emission from the optics themselves can add background signal in the long-wave band. Request temperature-characterised data if your system operates across a wide range.

Tell us your wavelength band, detector type, operating temperature and environment. Our team can recommend an IR substrate, filter or window from our range, or quote a custom component with measured transmission data.

#infrared#materials#filters